Green 3.6V Ni MH Battery High Temperature Type for Radar Detector
Product Details:
Place of Origin: | Guangzhou |
Brand Name: | TAC |
Certification: | MSDS REACH |
Model Number: | 60H3B6H |
Payment & Shipping Terms:
Minimum Order Quantity: | 500 PCS |
---|---|
Price: | PRICE NEGOTIABLE |
Packaging Details: | 50PCS/BOX |
Delivery Time: | 10-25 days |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | 500000pcs per week |
Detail Information |
|||
High Light: | nickel metal hydride nimh batteries,nickel metal hydride nimh batteries |
---|
Product Description
Green 3.6V Ni MH Battery High Temperature Type for Radar Detector
Datasheet:
Model |
Voltage |
Capacity |
Recommended |
Nominal |
Normal |
Nominal |
Weight |
60H3B6H(JST) |
3.6V |
80mAh |
2.4~4mA |
8mA |
14~16h |
16mA |
11.2g |
- CELL AND TYPE
- Cell : Sealed Ni-MH Button Cell
- Type : Button type
- Size type : 3.6V
- RATINGS
- Nominal voltage : 3.6V
- Nominal capacity : 80mAh
- Typical weight : 11.2g
- Standard charge : 8mA×14hours
- Rapid charge : 16mA×6hours
Trickle current : 2.4mA
- Discharge cut-off voltage: 3.0V
- Temperature range for operation (Humidity: Max.85%)
Standard charge 0 ~ +45℃
Rapid charge +10 ~ +45℃
Trickle charge 0 ~ +45℃
Discharge -10 ~ +45℃
3.8 Temperature range for storage (Humidity: Max.85%)
Within 2 years -20 ~ +35℃
Within 6 months -20 ~ +45℃
Within a month -20 ~ +45℃
Within a week -20 ~ +55℃
- ASSEMBLY & DIMENSIONS
Per attached drawing
- PERFORMANCE
- TEST CONDITIONS
The test is carried out with new batteries (within a month after delivery)
ambient conditions
Temperature: +25 ± 5℃
Humidity: 60 ± 20%
Note 1
Standard charge : 8mA×14hours
Standard discharge : 16mA to 3.0V
TEST METHOD & PERFORMANCE
Test |
Unit |
Specification |
Conditions |
Remarks |
Capacity |
mAh |
≥80 |
Standard |
Up to 3 cycles |
Open Circuit |
Voltage |
≥3.9 |
After 1 hour standard |
|
Internal |
mΩ/cell |
≤1500 |
Upon fully charge |
|
High rate |
Minute |
≥60 |
Standard charge |
|
Discharge |
mA |
40 |
Maximum continuous |
|
Over charge |
|
No leakage |
2.4mA charge |
|
Charge |
mAh |
64 |
Standard charge; |
|
Cycle Life |
Cycle |
≥400 |
IEC/CEI61951-2:2001. 4.4 |
|
Leakage |
|
No leakage nor |
Fully charge at 8mA, |
|
Note 2 IEC/CEI61951-2:2001. 4.4 cycle life
Cycle number |
Charge |
Stand in charged Condition |
Discharge |
1 |
8mA for 16h |
None |
20mA for 2h20min |
2-48 |
20mA for 3h10min |
None |
20mA for 2h20min |
49 |
20mA for 3h10min |
None |
20mA to 1.0V/cell |
50 |
8mA for 16h |
1h to 4h |
16mA to 1.0V/cell |
1.Befor the endurance in cycles test, the cell shall be discharged at 16mA to a final voltage of 1.0V/cell. |